fan

fan

2017年3月20日星期一

The fan of the purchase skills

1. Look at random files Each fan's random file includes the instruction manual, product certification, electrical circuit diagram and packing list, the purchase should be in accordance with the packing list inventory, check the number and quality of parts.
2. Look at the screen and the exhaust window fans is obvious deformation in the assembly of the fan fan cover, with a pen pointing to the highest point of a fan, slowly move the fan, the other few leaves corresponding to the tip of the pen The distance should be very close, and then turn the fan, pay attention to observe whether the rotation is light and flexible, and can stop at any position.
3. To see whether the control mechanism is flexible control mechanism including speed control switch, timing knob, shaking his head switch, lighting switch, etc., these control agencies should be flexible operation, reliable contact. On the speed control, do not allow two blocks at the same time connected or a block can not go on the phenomenon. Press the stop button, the speed of the key should be normal reset.
4. Look at the activities of some of the performance fan fan head overlooking the angle of the operation of flexible, tight lock, adjust to the maximum angle or shaking his head to the final position, the net cover are not collided with the fan pillars. Fan operation, the stability is better, can not be dumped, shaking his head should not be less than 60-80 degrees.
5. Start performance performance Start performance is an important fan of quality indicators. Inspection, should be transferred in the slow speed, and the power supply rated voltage of 85%, that is, with a voltage regulator to 220 volts to 187 volts to start the fan, electric industrial fans should be able to start from the static, and normal operation, The shorter the time required for a fan to start from normal operation, the better the start-up performance of the fan motor.
6. To see the operation and speed performance power after the shaking his head switch back and forth several times to check whether the failure or assembly too tight, in this process, the fan mechanical transmission part should not have abnormal noise. Fan in high, medium and low speed operation, the motor and fan should be smooth, small vibration, low noise. Fan shaking his head, shut down should be agile, no intermittent, stagnation and jitter phenomenon, the block speed difference should be obvious, the air angle the greater the better. When the fan stops, the shaft axial clearance does not exceed 0.5 cm, the gap is too large, the operation will cause axial movement and impact sound.
7. to see if the leakage of electric power, if the hand touched a strong hemp inductance, test with a pen test, test pen will be light display, can determine the shell leakage, can not be used.
8. to see the continuous operation of the fan performance Fan continuous operation after 2 hours, if the nose shell surface hot, indicating that the temperature is too high, can not be selected. Under normal circumstances, the nose shell surface temperature below 50 ℃, there will be no very hot feeling.

2017年3月13日星期一

Five-leaf bath ventilator fans, by the Northwestern Polytechnic University aerodynamics expert Professor Sidko use the aircraft wings, propeller principle, to explore a set of the best fan blade bend, sweep angle, the most favorable center of gravity line shape and Blade plane shape. Using these fan design techniques, the design of the fan has a significant high efficiency, low noise characteristics.
As the "cut" the wind is more uniform, the use of "five leaves" of the fan not only brings a mute effect, from the comfort point of view also more choices. Fan fan can be achieved when a wider range of multi-block adjustment. Most of the "three leaf fan" is basically a third block of wind regulation, "five leaf heater with fans" can be more than a block.
Especially in the lower operation of the block, the air is not very violent, you can avoid the fan blowing easy to cool the problem, and from the energy point of view is still very good. It is understood that the United States, "five leaves mute" electric fans as an example, energy efficiency standards can be achieved 1 16 talent platform fan air volume than the national standard increased by 27%, noise than the national standard reduced 15.8%; click power is also reduced 11.4%, energy efficiency ratio increased by 24%.

2017年3月6日星期一

The shape and principle of the oil and oil are similar to those of the parents. It is the purpose of heating and heating by heating the heating oil in the machine. The structure of the oil is similar to that of the radiator. Therefore, the relationship between the number of electric heaters for home plates and the heating effect Very close.

2017年2月27日星期一

European-style hot stove seems to be more tall and more, by understanding its general characteristics In fact, Xiaobian also more inclined to introduce this type of electric house heater to everyone. Its structure is similar to the oil Ting, but the heating source replaced by the heating wire, the volume compared to the petrol to petite some. European-style hot stove without a fan, the heat through the hot air rising away from the top of the cooling hole natural discharge, so there is no need to take the initiative to open the wind noise embarrassment, and the other electric heating without light, so it will not disturb Sleep.

2017年2月20日星期一

Working Principle of LPG Heater

As the name suggests, liquefied indoor electric heater is the use of liquefied petroleum gas as fuel, it burns ceramic plates or stainless steel furnace direct heat. There is a long fire, which has been burning to maintain the state in order to prevent aggregation explosion. By the thermocouple magnetic valve control, but the fire out, immediately closed. LPG heater with low oxygen protection and anti-dumping protection device. It discharges CO2 and water, so if it is straight, you need to keep the room ventilated.

2017年2月16日星期四

A: full combustion, high thermal efficiency using infrared combustion patented technology to achieve a deep purification combustion, combustion rate of 100%, combustion heat conversion efficiency of 99% or more. Because it is directly on the home electrical heaters, can greatly reduce energy consumption, compared to air-conditioning can save more than 50%.
2: heat, heat quickly from 1.4KW per hour electrical indoor heater to 4.2KW, and energy-consuming heating equipment (such as air conditioning) than in a shorter time to room
Within the desired temperature. In this case,
Three: multiple safety devices are from Italy, to ensure that your family and health and safety
A, low oxygen automatic flameout device. When the indoor oxygen content fell to 19.2% -19.7%, the device starts, automatically cut off the gas source and turn off;
B, vibration, dumping automatic flameout device. In this case,
C, flameout automatically cut off the gas source device. Due to unexpected reasons (such as wind) and lead to flameout, the device starts automatically cut off the gas source;

2017年2月12日星期日

The use of tubular energy efficient room heaters components: the external armored steel protection, filled with high-quality composite magnesium powder, the center is made of special alloy heating resistor, the external design with a special high-strength aluminum alloy plate integrated into the radiation heat dissipation Plate assembly to constitute a gas indoor heaters element assembly. When the power supply is turned on, the metal-covered resistor together with the heat sink generates heat in the interior of the device, the center of the heat source causes the radiator to heat and the surrounding object is radiated and heated through the vents in front of the device Convection heating air, double heating, so that the installation of the equipment room heat and the required temperature is guaranteed. The machine and thermostat are easy to install and use, and can be equipped with automatic programmable liquid crystal display wall thermostat and other wall thermostats.